PQ Plus UMD 705E Digital rail-mount meter

795,99 €
VAT included
Free shipping
Delivery time: 1-2 days
in stock
Free return shipment until 31.01.2026
PQ Plus UMD 705E Digital rail-mount meter
795,99 €
VAT included
Free shipping
One article is not enough for you and you want to save money?
from 3 piece: 788,03 € 1,0% savings
from 5 piece: 780,07 € 2,0% savings
from 10 piece: 772,11 € 3,0% savings

Product description

Overview

Interface: Ethernet, RS485
Communication: Modbus TCP/IP, Modbus RTU
Integrated Web Server
1 digital input, 2 digital outputs
LCD color display
Memory: 512MB Flash
3 voltage and 3 current inputs
Harmonious each order 1. 50. For U/I
In conjunction with module PQS: measurement and recording of power quality according to EN 50160

Description

The UMD705 is a compact power quality meter with data logger for mounting on the DIN rail. It measures 3-phase current and voltage with up to 3 tariffs in 4-quadrant operation and the work in Class 0.2 s, as well as all usual network variables, e.g. harmonics up to the 50 most harmonic. It forms the option of power quality according to EN 61000-2-2, EN 61000-2-4, EN 61000-2-12 with the PQ S firmware module. It has a large 512 MB memory. Via the Ethernet interface, the device is accessed, and the associated web server live measured values via the web browser. Thus are also internet protocols can also be scanned in and it can be easily connected PLC and building control systems Digital inputs/outputs and a serial RS485 interface are integrated. The UMD 705 can also be used as a Modbus master to bind up to 31 Modbus slaves in network structures can be used. With the optional firmware module GO to oscilloscope functions for current and voltage is activated and trigger signals for limit value events.

Characteristics

Measuring:
Voltage (ULL; ULN): U1;U2, U3, U12, U23, U31 class 0.2
Current IL1;IL2; IL3; Class 0.5
Active/Reactive Power Import/Export per phase L1, L2, L3, T1, T2, T3 per tariff
Active power: P1, P2, P3;3 P import; export; Class 1
Reactive power: Q1, Q2, Q3; 3Q; Class 1
Apparent power: S1; S2; S3; 3S; Class 1
Harmonic distortion performance: D1, D2, D3;
Power factor Cos phi: PF1, PF2;, PF3, PF, Cos phi 1, cos phi2, cos phi 3; Class 0.5
Symmetry: yes
THDU THDU harmonic voltage: 1; 2; 3; THDU THDU 12; 31; 23; THDU THDU T. 2
THDI harmonic current: 1; 2; 3; T. 2 THDI THDI
Harmonious each order: 1. to 50. For U/I
Distortion: U1 fh; U2 fh; U3 fh; Unfh; I1 fh; I2FH; I3 fh; Infh
Frequency: 40...70 Hz class 0.05
Effective: 4-quadrant measurement Import/Export per phase; per tariff; total; Class 0.5S
Reactive energy: 4-quadrant measurement Import/Export per phase; per tariff; total; Class 2
Flicker Option: PQ S

Data logger:
512 MB memory (Flash): ULN; ULL; I; P;Q;S;D;THDU; THDI;F;Ufh; Status I/O
Energy: Active/Reactive Power Import/Export per phase L1, L2, L3, T1, T2, T3 per tariff
Voltage dips: Option: PQ S
Oscillogram function: Option: GO

Additional functions:
Alarms: logic; limit values for exceeding or falling short of
I/O: 2 DIO's; 60 V AC/100 V DC, 300 mA;
Memory: 512MB Flash
Recording interval sec; min; h, Day, Month, Year
Communication RS 485 Modbus, Ethernet 100 MBit/s

Electrical connection
Supply voltage: U: 85...510 V AC/85...350 V DC
Power consumption 7 VA/3W
Overvoltage category: CAT III 300 V

Measuring ranges:
Nominal voltage: 180 ... 280 V AC
Overload: 1.95 kV LN/1 s
Impedance: 2.7 MOhm
Input signal: X/1//5 A
Overcurrent: 1.2x in (max. 70 A/1 s)
Sampling rate: 25.6 kHz
PQ analysis: Option: EN 50160, EN 61000-2-2, EN 61000-2-4, EN 61000-2-12

Ambient conditions:
Temperature rang

Delivery content

  • UMD 705 E
  • Energy management software ENVIS. Basic
  • Configuration Tool ENVIS. daq

Keywords

04053199531745, PQ Plus, 11.17.1104, UMD 705E, Universal measuring device, DIN rail measuring device

Product specifications

Downloads

Reviews

Accessories / similar products

{{#if results}}