Product description
Overview
Interface: Ethernet, RS485 Communication: Modbus TCP/IP, Modbus RTU Integrated Web Server 1 digital input, 2 digital outputs LCD color display Memory: 512MB Flash 3 voltage and 3 current inputs Harmonious each order 1. 50. For U/I In conjunction with module PQS: measurement and recording of power quality according to EN 50160
Description
The UMD705 is a compact power quality meter with data logger for mounting on the DIN rail. It measures 3-phase current and voltage with up to 3 tariffs in 4-quadrant operation and the work in Class 0.2 s, as well as all usual network variables, e.g. harmonics up to the 50 most harmonic. It forms the option of power quality according to EN 61000-2-2, EN 61000-2-4, EN 61000-2-12 with the PQ S firmware module. It has a large 512 MB memory. Via the Ethernet interface, the device is accessed, and the associated web server live measured values via the web browser. Thus are also internet protocols can also be scanned in and it can be easily connected PLC and building control systems Digital inputs/outputs and a serial RS485 interface are integrated. The UMD 705 can also be used as a Modbus master to bind up to 31 Modbus slaves in network structures can be used. With the optional firmware module GO to oscilloscope functions for current and voltage is activated and trigger signals for limit value events.
Characteristics
Measuring: Voltage (ULL; ULN): U1;U2, U3, U12, U23, U31 class 0.2 Current IL1;IL2; IL3; Class 0.5 Active/Reactive Power Import/Export per phase L1, L2, L3, T1, T2, T3 per tariff Active power: P1, P2, P3;3 P import; export; Class 1 Reactive power: Q1, Q2, Q3; 3Q; Class 1 Apparent power: S1; S2; S3; 3S; Class 1 Harmonic distortion performance: D1, D2, D3; Power factor Cos phi: PF1, PF2;, PF3, PF, Cos phi 1, cos phi2, cos phi 3; Class 0.5 Symmetry: yes THDU THDU harmonic voltage: 1; 2; 3; THDU THDU 12; 31; 23; THDU THDU T. 2 THDI harmonic current: 1; 2; 3; T. 2 THDI THDI Harmonious each order: 1. to 50. For U/I Distortion: U1 fh; U2 fh; U3 fh; Unfh; I1 fh; I2FH; I3 fh; Infh Frequency: 40...70 Hz class 0.05 Effective: 4-quadrant measurement Import/Export per phase; per tariff; total; Class 0.5S Reactive energy: 4-quadrant measurement Import/Export per phase; per tariff; total; Class 2 Flicker Option: PQ S
Data logger: 512 MB memory (Flash): ULN; ULL; I; P;Q;S;D;THDU; THDI;F;Ufh; Status I/O Energy: Active/Reactive Power Import/Export per phase L1, L2, L3, T1, T2, T3 per tariff Voltage dips: Option: PQ S Oscillogram function: Option: GO
Additional functions: Alarms: logic; limit values for exceeding or falling short of I/O: 2 DIO's; 60 V AC/100 V DC, 300 mA; Memory: 512MB Flash Recording interval sec; min; h, Day, Month, Year Communication RS 485 Modbus, Ethernet 100 MBit/s
Electrical connection Supply voltage: U: 85...510 V AC/85...350 V DC Power consumption 7 VA/3W Overvoltage category: CAT III 300 V
Measuring ranges: Nominal voltage: 180 ... 280 V AC Overload: 1.95 kV LN/1 s Impedance: 2.7 MOhm Input signal: X/1//5 A Overcurrent: 1.2x in (max. 70 A/1 s) Sampling rate: 25.6 kHz PQ analysis: Option: EN 50160, EN 61000-2-2, EN 61000-2-4, EN 61000-2-12