Micro load cell
0-5kg measuring range
0.05% accuracy
Compatible to the Load Cell Bricklet
Micro load cell
0-5kg measuring range
0.05% accuracy
Compatible to the Load Cell Bricklet
This micro load cell is compatible with Load Cell Bricklet 2.0.
Measuring range: 0kg to 5kg
Nominal output ratio: 1.0±0.15mV/V
Non-linearity: 0.05%FS
Hysteresis: 0.03%FS
Repeatability: 0.05%FS
Drift: 0.05%FS/10min
Temperature effect at zero point: 0.03%FS/10°C
Temperature effect over measuring range: 0.02%FS/10°C
Zero point balance: ±1.0%FS
Input impedance: 1000±10Ω
Output impedance: 1000±3Ω
Insulation resistance: ≥ 2000MΩ at 100V (DC)
Recommended Excitation voltage: 3V to 10V (DC)
Permitted Excitation voltage: 3V to 18V (DC)
Compensated temperature range: -10°C to +40°C
Operating temperature range: -20°C to +60°C
Limit range Overload: 120%FS
Maximum overload: 150%FS
Connections: Excitation+: Red; Excitation-: Black; Signal+: Green; Signal+: White