SONEL
- 2-, 3- and 4-pole earth measurement - 3-pole earth measurement with a clamp - Earth measurement with 2-clamps without disconnecting the earth - Specific resistance - Current measurement with clamps - Earth measurement with auxiliary electrodes RS and RH - Protective conductor resistance measurement with 200 mA - Measurement of interference voltages in networks with 50 Hz, leakage current measurement - 60 Hz - Measurement voltage 24 V or 50 V - Distance in meters (m) or feet (ft) - Real time clock (RTC) - USB connection
This offer is only valid for business customers
- Loop impedance measurement with a resolution of 0.01 Ω
- Loop impedance measurement in networks that are secured with a FI switch ≥30 mA with a resolution of 0.01 Ω (180 to 270 V)
- Measurement in mains 220/380 V, 230 V/400 V, 240/415 V (range 180 to 460 V)
670,79 €
VAT included
Free shipping
Delivery time:
2-3 days
in stock
- network quality analysis: IEC61000-4-30, Class S - DIN EN 50160 - Measurement of all important network parameters such as..: V, A, P, Q, D, S, f, E, cosϕ, PF, tgϕ, THD, TID, Pst, Plt - Measurement in networks from 64V-760V with 40-70Hz - Measurements up to the 40th harmonic - Digital recording of power curves and waveforms - Working temperature: -20...55°C
This offer is only valid for business customers
- network quality analysis: IEC61000-4-30 Class A;DIN EN 50160;DIN EN 61000-4-7;DIN EN 61000-4-15;Measurement of all important network parameters: V, A, P, Q, D, S, f, E, cosϕ, PF, tgϕ, THD, TID, K-factor, PST, PLT;Ripple control signals up to 3 kHz;Digital recording of waveforms;Measurement in networks of 64V-760V with 40Hz-70Hz;Data transmission via GSM (GPRS);Integrated GPS receiver for RTC synchronization;Theft protection by SMS warning;Working temperature: -20...55°C
This offer is only valid for business customers
- To facilitate diagnosis, one of the EVSE-01 jacks provides a pulse width modulation (PWM) signal.
- The EVSE-01 adapter enables measurements at electrical AC charging stations with type 2 connection. Tests are available on 1-phase and 3-phase stations - with and without ventilation.
This offer is only valid for business customers
- Measurement current up to 10 A · Resolution up to minimum 1 µΩ · 3 different measurement modes (normal, car, cont.) · Measurement of resistive and inductive objects · 4-wire measurement · No influence due to interference. · Adjustable limits (min/max).
This offer is only valid for business customers
- Loop impedance measurement with max. 41 A at 415 V · Loop impedance test without tripping the RCD · Short-circuit current calculation · Insulation resistance measurement with max. 1000 V up to 10 GΩ · Protective earth resistance measurement with ± 200 mA · RCD/FI type AC, A and B up to 1000 mA · TRMS current measurement up to 400 A · AC voltage measurement up to 500 V · Effective, apparent and reactive power measurement including p.f. · Earthing measurement with 2 clip-on ammeter without disconnecting of the erders by the wenner Method Method · Specific earth resistance ρ · Lighting Measurement · Rotary field indicator; · Power quality analysis
Currently not available